Answer:
[tex]D=0.41m[/tex]
Explanation:
From the question we are told that:
Discharge rate [tex]V_r=0.35 m3/s[/tex]
Distance [tex]d=4km[/tex]
Elevation of the pumping station [tex]h_p= 140 m[/tex]
Elevation of the Exit point [tex]h_e= 150 m[/tex]
Generally the Steady Flow Energy Equation SFEE is mathematically given by
[tex]h_p=h_e+h[/tex]
With
[tex]P_1-P_2[/tex]
And
[tex]V_1=V-2[/tex]
Therefore
[tex]h=140-150[/tex]
[tex]h=10[/tex]
Generally h is give as
[tex]h=\frac{0.5LV^2}{2gD}[/tex]
[tex]h=\frac{8Q^2fL}{\pi^2 gD^5}[/tex]
Therefore
[tex]10=\frac{8Q^2fL}{\pi^2 gD^5}[/tex]
[tex]D=^5\frac{8*(0.35)^2*0.003*4000}{3.142^2*9.81*10}[/tex]
[tex]D=0.41m[/tex]
Question 1. If a fiber weight 3.0 g and composite specimen weighing 4.g. The composite specimen weighs 2.0 g in water. If the specific gravity of the fiber and matrix is 2.4 and 1.3, respectively, find the 1. Theoretical density of composite 2. Experimental density 3. Void fraction
Answer:
Explanation:
From the given information:
weight of fiber [tex]w_f[/tex] = 3.0 g
weight of composite specimen [tex]w_c[/tex] = 4.0 g
specimen composite weight in water [tex]C_{wm}[/tex] = 2.0 g
specific gravity of fiber [tex]S_f[/tex] = 2.4
specific gravity of matrix [tex]S_m[/tex] = 1.3
The weight of the matrix = weight of the composite - the weight of fiber
⇒ (4.0 - 3.0) g
= 1.0 g
The theoretical density of the composite [tex]\rho_{ct}[/tex] can be determined by using the formula:
[tex]\dfrac{1}{\rho_{ct}} = \dfrac{w_f}{w_cS_f}+ \dfrac{w_m}{w_cS_m}[/tex]
[tex]\dfrac{1}{\rho_{ct}} = \dfrac{3.0}{(4.0 \times 2.4)}+ \dfrac{1.0}{(4.0\times 1.3)}[/tex]
[tex]\dfrac{1}{\rho_{ct}} = \dfrac{3.0}{9.6}+ \dfrac{1.0}{5.2}[/tex]
[tex]\dfrac{1}{\rho_{ct}} =0.505\\[/tex]
[tex]\rho_{ct} =\dfrac{1}{0.505}[/tex]
[tex]\mathbf{\rho_{ct} = 1.980 \ g/cm^3}[/tex]
The experimental density [tex]\rho _{ce}[/tex] is determined by using the equation:
[tex]\rho _{ce} = \dfrac{w_f + w_c}{\dfrac{w_f }{S_f} + \dfrac{w_c }{S_m} }[/tex]
[tex]\rho _{ce} = \dfrac{3.0 + 4.0}{\dfrac{3.0 }{2.4} + \dfrac{4.0 }{1.3} }[/tex]
[tex]\rho _{ce} = \dfrac{3.0 + 4.0}{1.250 +3.077 }[/tex]
[tex]\mathbf{\rho _{ce} = 1.620 \ g/cm^3}[/tex]
The void fraction is: [tex]= \dfrac{\rho_{ct}-\rho_{ce}}{\rho_{ct}}[/tex]
[tex]= \dfrac{1.980-1.620}{1.980}[/tex]
= 0.1818
Carbon dioxide at a temperature of 0oC and a pressure of 600 kPa (abs) flows through a horizontal 40-mm- diameter pipe with an average velocity of 2 m/s. Determine the friction factor if the pressure drop is 235 N/m2 per 10-m length of pipe.
Answer:
f = 0.04042
Explanation:
temperature = 0°C = 273k
p = 600 Kpa
d = 40 millemeter
e = 10 m
change in P = 235 N/m²
μ = 2m/s
R = 188.9 Nm/kgk
we solve this using this formula;
P = ρcos*R*T
we put in the values into this equation
600x10³ = ρcos * 188.9 * 273
600000 = ρcos51569.7
ρcos = 600000/51569.7
=11.63
from here we find the head loss due to friction
Δp/pg = feμ²/2D
235/11.63 = f*10*4/2*40x10⁻³
20.21 = 40f/0.08
20.21*0.08 = 40f
1.6168 = 40f
divide through by 40
f = 0.04042